950 SERIES

950 SERIES2,5 – 90 KVAR/440 V 50 Hz

For networks with low/medium harmonic distortion
< 30% THD in current The 950 Series is a semi-automatic equipment that has been developed for fixed motor engines reactive energy compensation or facilities where there is a constant electrical load an automatic regulation is not required. TECHNICAL SPECIFICATIONS AND STANDARD EQUIPMENT Rated voltage: 440 V 50 Hz. Admissible working voltage range: 380 – 440 V. Automatic thermo-magnetic circuit breaker. Three-phase capacitors TR30 Series with internal safety system. Capacitor duty contactor. Capacitor on-line indicator lamps. Halogen-free cables. Top quality metal cabinet. OPTIONAL EQUIPMENT AND NON-STANDARD EQUIPMENTS Three-pole on-load circuit breaker and fuses. Specially protected cabinets for outdoor use (polyester, stainless steel, metal cabinets with high IP protection). Other power ratings, voltages available upon request. Check Sheet

2000 SERIES

2000 SERIES200 – 1000 KVAR/440 V 50 Hz

For networks with low/medium harmonic distortion
< 30% THD in current

Automatic capacitor bank for large facilities like big supermarkets,
commercial malls, sports stadiums, industrial factories, singular
buildings, airports, ports, hospitals, etc. The architecture of this
equipment is totally flexible based on our modular system 1000 Series,
which allows to increase the power even when already installed.

TECHNICAL SPECIFICATIONS AND STANDARD EQUIPMENT

Rated voltage: 440 V 50 Hz.
Admissible working voltage range: 380 – 440 V.
Power factor controller PFR-6 or PFR-12 equipped with microprocessor.
Capacitor duty contactors.
Three-phase capacitors TR30 Series with internal safety system.
Step protection fuses.
Copper busbars.
Built in fan for a better refrigeration of the bank.
Halogen-free cables.
Top quality metal cabinet.

OPTIONAL EQUIPMENT AND NON-STANDARD EQUIPMENTS

Specially protected cabinets for outdoor use (polyester, stainless steel, metal cabinets with high IP protection). Switching transformer.
Three-pole on-load circuit breaker or automatic thermo-magnetic circuit breaker.
Other power ratings, voltages, differential protection, steps or frequencies available upon request.

Check Sheet

300 SERIES

300 SERIES77,5 – 220 KVAR/440 V 50 Hz

For networks with low/medium harmonic distortion
< 30% THD in current

Automatic capacitor bank designed for medium sized installations.
Thanks to its reduced dimensions, it is the ideal solution for saving
energy in small hypermarkets, commercial malls, small hospitals,
workshops, small factories, sport centres, golf courses, etc.

TECHNICAL SPECIFICATIONS AND STANDARD EQUIPMENT

Rated voltage: 440 V 50 Hz.
Admissible working voltage range: 380 – 440 V.
Power factor controller PFR-6 equipped with microprocessor.
Automatic thermo-magnetic circuit breaker.
Capacitor duty contactors.
Three-phase capacitors TR30 Series with internal safety system.
Halogen-free cables.
Top quality metal cabinet.

OPTIONAL EQUIPMENT AND NON-STANDARD EQUIPMENTS

Specially protected cabinets for outdoor use (polyester, stainless steel, metal cabinets with high IP protection).
Switching transformer.
Other power ratings, voltages, differential protection, steps or frequencies available upon request.

Check Sheet