4000 SERIES

4000 SERIES22,5 – 500 KVAR/400 V 50 Hz

For networks with high harmonic distortion < 60% THD in current
Automatic capacitor bank specially designed to work in polluted
installations. This equipment is unique at absorbing harmonics distortion
without incorporating harmonic filters. The capacitors, contactors and
components used are suitably prepared for operation under problem
voltage and current conditions.

TECHNICAL SPECIFICATIONS AND STANDARD EQUIPMENT
Rated voltage: 400 V 50 Hz.
Admissible working voltage range: 380 – 400 V.
Power factor controller PFR-6 or PFR-12 equipped with microprocessor.
Capacitor duty contactors over dimensioned to work in networks with
harmonic distortion.
Three-phase capacitors TR30 Series with internal safety system, specially
designed to absorb harmonics distortion up to 60% THD in current.
Automatic thermo-magnetic circuit breaker is included up to 95 Kvar.
Step protection fuses (from 120 Kvar).
Built in fan for a better refrigeration of the bank. Halogen-free cables. Top quality metal cabinet.

OPTIONAL EQUIPMENT AND NON-STANDARD EQUIPMENTS
Specially protected cabinets for outdoor use (polyester, stainless steel, metal cabinets with high IP protection).
Switching transformer.
Automatic thermo-magnetic circuit breaker or three-pole on-load circuit breaker from 95 Kvar. Other power ratings, differential protection, voltages, steps or frequencies available upon request.

Cheek Sheet

20 SERIES

20 SERIES7,5 – 35 KVAR/440 V 50 Hz

For networks with low/medium harmonic distortion
< 30% THD in current

The ultimate automatic capacitor bank with the newest attractive
design. This is the ideal solution to eliminate the penalty for reactive
energy consumption in small installations without main board where
the equipment is shown to the public.
All kind of shops, coffee shops, pubs, restaurants, small markets,
language schools, hairdressing salons, etc. can now install our pretty
capacitor bank remaining the decoration of the business untouched.

TECHNICAL SPECIFICATIONS AND STANDARD EQUIPMENT
Rated voltage: 440 V 50 Hz.
Admissible working voltage range: 380 – 440 V.
Power factor controller PFR-6 equipped with microprocessor.
Automatic thermo-magnetic circuit breaker.
Capacitor duty contactors.
Three-phase capacitors TR30 Series with internal safety system.
Halogen free cables.
Top quality metal-plastic cabinet with attractive design.

OPTIONAL EQUIPMENT AND NON-STANDARD EQUIPMENTS
Other power ratings, voltages, steps or frequencies available upon request.

>Cheek Sheet

700 SERIES

700 SERIES2,5–20 KVAR/440 V 50 Hz

For networks with low/medium harmonic distortion
< 30% THD in current

Automatic capacitor bank with one or two steps. Ideal solution for
power factor correction in very small installations where connections
of different steps are no needed. Extremely easy usage and installation. With no doubt, it is the best solution for saving in small electrical installations.

TECHNICAL SPECIFICATIONS AND STANDARD EQUIPMENT
Rated voltage: 440 V 50 Hz.
Admissible working voltage range: 380 – 440 V.
Power factor controller PFR-200 with microprocessor and 5 levels for the
adjustment of the C/K value.
Capacitor duty contactors.
Three-phase capacitors TR30 Series with internal safety system.
Halogen-free cables.
Top quality metal cabinet.
Automatic thermo-magnetic circuit breaker.

OPTIONAL EQUIPMENT AND NON-STANDARD EQUIPMENTS
Specially protected cabinets for outdoor use (polyester, stainless steel, metal cabinets with high IP protection).
Other power ratings, voltages, steps or frequencies available upon request.

>Cheek Sheet