AE890 CP SERIES

AE89010 KVA–200 KVA III/III

Three-phase last generation UPS. Its medium and high power ratings
make this equipment the ideal solution for a myriad of applications
such as centralized server centres, network control centres, medical
devices, emergency centres, communication and information centres,
etc.

TECHNICAL SPECIFICATIONS AND STANDARD EQUIPMENT

True on-line dual conversion design.
Wide input voltage and frequency range.
Digital control technology.
High efficiency IGBT.
True sine wave output with less than 3% THD.
LCD display and acustic alarm.
Generator compatible.
Self-detection on start-up.
Integrated battery cabinet for standar back-up time.
Short circuit and overload protection.
Advanced battery management.
Filter at input and isolating transformer at output.
SNMP Optional.
RS232.
Dry slot.
Shutdown & restart schedule.
Up to 8 modules parallel.

Check Sheet

AE890 CL SERIES

AE890CL OEM160 KVA–300 KVA III/III

TECHNICAL SPECIFICATIONS AND STANDARD EQUIPMENT IGBT RECTIFIER

AE890 CL Series are three-phase in/three-phase out, IGBT rectifier,
technology based on intelligent power module, high input power factor and
low THDi.

• Low input current total harmonic distortion (THDi).
• High input power factor.
• High efficiency up to 94%.
• Cold start function.
• Static and maintenance by-pass switch.
• Output short circuit and overload protection.
• External REPO switch input.
• 128 events memory (128 events 3072 alarms).
• Clock and calendar (battery supported).
• Automatic battery test, remaining battery time indicator.
• Temperature compensated charge system.
• Modem configuration for dial.
• RS232 serial port and dry contact outputs.
• Transformerless UPS topology.
• Optional isolation transformer for input and output.
• Optional SNMP and MODBUS adaptors.
• Parallel operation up to 4 devices.
• Manufactured according to EC Directive; EN62040.

Check Sheet

AE860 D SERIES

AE860 D10 kVA – 20 kVA III/I

TECHNICAL SPECIFICATIONS AND STANDARD EQUIPMENT
Digital control technology to achieve parallel redundancy function.
High Reliable Parallel Technology.
Miniaturization design: Advanced control technology improves the power
factor, compact size and light weight.
On-Line maintenance.
Intelligent charging management mode prolongs the battery life to save
expense.
Automatic restart function can start UPS automatically after battery
discharged fully.
P.F. = 0,99 improves the main using efficiency, which is true green power.
Wide input voltage range.
Nearly 90% operation efficiency.
IEC61000-4 EMI approvals.
Support Microsoft: Windows95/98/Me/NT/2000/XP/Linux operation
systems and is fit for TCP/IP LAN, and support TCP/IP network monitor UPS.
Detects the UPS model and the communication interface automatically.
AE860 D Series installs one intelligent slot. SNMP (optional).

Check Sheet