Sobre nosotros
AENER ENERGÍA nace en Madrid (España) en 1994 como fabricante de condensadores de potencia, baterías automáticas de condensadores, equipos de calidad de red como SAI´s – UPS´s y estabilizadores de voltaje.
Aener Energía
Calle Canarias, 8
28864 Ajalvir
España
+34 916 68 03 30
comercial@aener.com
Horario
Lunes a Jueves: 8:00-17:00 horas
Viernes: 9:00-14:00 horas
CNNK SERIES
/en Power Factor Correction /por arancha5 – 50 KVAR/240–660 V 50 Hz
This contactor is specially designed to work for capacitive current
switching. It is strong and durable.
TECHNICAL SPECIFICATIONS
Maximum working voltage: 690 V.
Voltage tolerance: – 20 + 20%.
Life expectancy under optimal conditions: > 200.000 times.
Admissible temperature: Max. 55°C / Min. –25°C.
Check Sheet
SMC SERIES
/en Power Factor Correction, Product /por arancha6,7–60 KVAR/240–600 V 50 Hz
Why special capacitor duty contactor?
During the exact moment of switching, a capacitor effectively appears
as short circuit. In case of multi-stage capacitor, for automatic
capacitor banks, the in-rush current greater than 180 times the rated
capacitor current can occur.
Such large-current of such high magnitude is undesirable and likely
to weld main contacts of standard duty contactors and even damage
capacitors. That is why, we advise to use our special capacitor duty
contactors.
TECHNICAL SPECIFICATIONS
Rated insulation voltage: 660 V.
Maximun working voltage: 600 V.
Voltage tolerance: – 20 + 20%.
Life expectancy under optimal conditions: >100.000 times.
Operation frequency: up to 240 (depending on types).
Admisible temperature: Max. 45°C / Min. – 5°C.
Check Sheet
LTC-16 SERIES
/en Power Factor Correction /por arancha16 steps
Reactive Energy Controller LTC-16
It has got the latest technology in measurement and control of power
factor. It controls up to 16 steps, measuring and regulating the cos φ in
slots, independently.
Ideal to work in PV power plants, wind energy, hydraulic system or other
renewable energy sources and cogeneration
MAIN CHARACTERISTICS
Switching up to 16 stages of capacitor banks.
Multiple readings and protection’s alarms.
Up to 6 months of energy data logging (voltage, current, harmonics …)
Accuracy: 0,2%.
Real measurement per phase.
High resolutions display 128X64 pixels.
RS485 communication port.
Modbus protocols.
TECHNICAL SPEC IFICATIONS
Input voltage: 0 – 650 V.
Supply voltage: 90 – 250 V.
Frequency: 50/ 60 Hz.
Maximum input current: 6 A.
Admissible temperature: Max. 70°C. / Min. –20°C.
Weight (approx.): 1,00 kg.
Check Sheet